Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 87: 384-6, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24332341

RESUMO

The correlation method (Suvaila et al., 2013) is extended to the assessment of (60)Co and (134)Cs point sources embedded in non-homogeneous samples. Experimental data reveal a strong correlation between the efficiency ε(1173 keV) and the ratio of the count rate R in the sum peak of 2505 keV and in the peak of 1332 keV. The correlation pattern and the measured R(2505)/R(1332) give unbiased values for ε(1173 keV), independent of source position and sample matrix. Monte Carlo simulations for (60)Co and (134)Cs support this conclusion.

2.
Appl Radiat Isot ; 81: 76-80, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23562436

RESUMO

In this work a method for the evaluation of the activity when a point source containing (60)Co is located in an unknown position within a sample is developed. The method can be applied if the count rate in the 2,505 keV sum peak has an acceptable uncertainty. It is based on the correlation between the apparent efficiency for the 1,173 keV peak and the ratio of the count rate in the sum peak of 2,505 keV and in the 1,332 keV peak. The correlation was observed in the measurements of a (60)Co point source located in various positions in a soil sample. The measurements were done with a 47% efficiency n-type HPGe detector. The correlation is also observed in the measurements and simulations done with a Compton-suppressed spectrometer having a 100% n-type HPGe detector. The results obtained with the proposed method are less affected by the uncertainty of the position of the point source than the results obtained using the standard methods of activity evaluation.


Assuntos
Algoritmos , Radioisótopos de Cobalto/análise , Interpretação Estatística de Dados , Poluentes Radioativos do Solo/análise , Espectrometria gama/métodos , Doses de Radiação , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Distribuições Estatísticas
3.
Appl Radiat Isot ; 81: 87-91, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23566809

RESUMO

The application of GEANT 4 and GESPECOR Monte Carlo simulation codes for efficiency calibration of in situ gamma-ray spectrometry was studied. The long computing time required by GEANT 4 prevents its use in routine simulations. Due to the application of variance reduction techniques, GESPECOR is much faster. In this code specific procedures for incorporating the depth profile of the activity were implemented. In addition procedures for evaluating the effect of non-homogeneity of the source were developed. The code was validated by comparison with test simulations carried out with GEANT 4 and by comparison with published results.


Assuntos
Algoritmos , Modelos Estatísticos , Método de Monte Carlo , Software , Espectrometria gama/métodos , Simulação por Computador , Doses de Radiação , Espalhamento de Radiação
4.
Appl Radiat Isot ; 70(9): 2144-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22406223

RESUMO

Several problems concerning (133)Ba activity distribution in a cylindrical source were addressed by measurements with a 47% n-type HPGe detector and by simulation. Within-sample homogeneity was tested using the count rates from normal and from pure sum peaks. The sensitivity of front versus back source measurements to deviations from uniform distribution was studied. In the case of distributions symmetric with respect to the median plane of the source quantities that can provide information on the distribution of the activity were proposed.


Assuntos
Algoritmos , Artefatos , Radioisótopos de Bário/análise , Radioisótopos de Bário/normas , Radiometria/normas , Manejo de Espécimes/instrumentação , Espectrometria gama/normas , Brasil , Doses de Radiação , Tamanho da Amostra
5.
J Chromatogr A ; 1217(12): 1977-87, 2010 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-20149381

RESUMO

Research on the chemical composition of fossil resins has evolved during the last decades as a multidisciplinary field and is strongly oriented toward the correlation with their geological and botanical origin. Various extraction procedures and chromatographic techniques have been used together for identifying the volatile compounds contained in the fossil resin matrix. Hyphenation between thermal desorption (TD), gas chromatography (GC) and mass spectrometry detection (MS) has been chosen to investigate the volatile compounds fraction from ambers with a focus on Romanite (Romanian amber) and Baltic amber species. A data analysis procedure was developed for the main purpose of fingerprinting ambers based on the MS identity of the peaks generated by the volatile fraction, together with their relative percentual area within the chromatogram. Chromatographic data analysis was based entirely on Automated Mass Spectral Deconvolution &Identification System (AMDIS) software to produce deconvoluted mass spectra which were used to build-up a mixed mass spectra and relative retention scale library. Multivariate data analysis was further applied on AMDIS results with successful discrimination between Romanite and Baltic ambers. A special trial was conducted to generate pyrolysis "like" macromolecular structure breakdown to volatile compounds by gamma irradiation with a high absorbed dose of 500 kGy. Contrary to our expectations the volatile fraction fingerprints were not modified after irradiation experiments. A complementary non-destructive new approach by ESR spectroscopy was also proposed for discriminating between Romanite and Baltic ambers.


Assuntos
Âmbar/química , Fósseis , Cromatografia Gasosa-Espectrometria de Massas/métodos , Fenômenos Geológicos , Temperatura , Compostos Orgânicos Voláteis/análise , Varredura Diferencial de Calorimetria , Espectroscopia de Ressonância de Spin Eletrônica , Análise Multivariada , Análise de Componente Principal , Termogravimetria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...